Measurement of Particle Shape and Size with Dynamic Image Analysis

The new ANALYSETTE 28 ImageSizer (Fig. 1) is suitable for analysis of particle shape and size of dry, free-flowing powders and bulk solids in a measuring range from 20 µm to 20 mm. Via the optical analysis of particle shape and particle size, damaged particles, contaminates, agglomerates or oversized- or undersized-particles are recognized accurate and fast and can be viewed as single images. At the same time, the instrument offers a fast and efficient particle size measurement. The measuring time, depending on the sample quantity, is below 5 minutes and the result is available immediately. The presentation of the sieving results conform to standards, is directly included in the FRITSCH-analysis software ISS.

Fast Analysis of Particle Shape and Size

Extra wide measuring range 20 μm–20 mm, individually adaptable

High-performance camera with telecentric lenses

Extensive library for morphological analysis

Practical tools for reliable quality monitoring

Fast, simple operation via SOP control

Freely editable report generator for individual measurement reports

The core of the ANALYSETTE 28 ImageSizer is a 5 mega-pixel camera. The telecentric lenses guarantee images of each individual particle free of distortions and always in the same reproduction scale – no matter where it is located in the measurement volume. The U-shaped cross section of the conveyance channel ensures a good material flow. The included sample guiding plates guarantee that the sample material even at a rapid conveyance rate drops into the falling chute at the optimum depth of field of the lens. The AutoCheck function displays the particle concentration and therefore the ideal feed rate (Fig. 2) of the sample on the conveyance channel. Your advantage: always the optimum number of particles per image for a reliable and significant analysis.

Even evaluation of the measuring results is very simple with the ANALYSETTE 28. The analysis software ISS shows each captured particle clearly as a data point in the cloud-shaped FRITSCH-Cloud. The position of the particle in this cloud shows the really important information about the morphology. It is possible to select the conclusions of interest: roundness in regards to the minimum Feret diameter, the aspect ratio, applied on the porosity or the convexity as a function of the cross section of the particle. Several measurements could be displayed simultaneously in a chart to immediately recognise the differences between the respective samples.

The freely configurable Report Generator enables automatically displaying the results clearly arranged on the monitor – optionally as a cloud, as cumulative curve, as bar diagram or in table form. Alternatively it is possible to use the predefined layout according the stipulations of the sieve analysis. The displayed information will be printed however it has been set up on the monitor.

www.fritsch-sizing.de

x

Related articles:

Issue 10/2012

Measurement of particle shape and size with dynamic image analysis

The new FRITSCH ANALYSETTE 28 does not only measure the particle size but also supplies reliable statements about the particle shape, via Dynamic Image Analysis. This is ensured by the integrated...

more

3D particle analysis reveals true morphology

Microtrac introduces the latest generation of dynamic image analyzers in the CAMSIZER series: The CAMSIZER 3D provides a ground-breaking innovation in particle characterization with a true...

more
Issue 04/2013

FRITSCH GmbH

FRITSCH, an internationally respected manufacturer of application-oriented laboratory instruments for sample preparation and particle sizing, presents the entire spectrum for efficient size-reduction...

more
Issue 11/12/2008

Fritsch Laser-Particle Measurement Analysette 22

25 Years Laser-Technology

In 1985 FRITSCH revolutionised measurement precision by introducing laser diffraction in a convergent laser beam with the patented FRITSCH measurement process. The advantage of this patented FRITSCH...

more
Issue 09/2020

Inexpensive and with a unique measuring range from 0.01 – 3800 µm

The ANALYSETTE 22 NeXT  is ideal for particle size analysis in production and quality control, research and development or for controlling manufacturing processes.  With the completely revised...

more